AMPERAGE/OHM VALUE CHARTS
NOTE:
Resistance measurements are taken across coil of relays and terminal ends on
heaters. Wires must be removed from component prior to resistance check.
OHM CHART
Mercury Relay
Watlow
Duracool
Electromechanical Relay
Heater - 208V, 3500W
AMPERAGE CHART
CAUTION: 208 Volt Fryers are not to be used in single phase applications. Current produced
exceeds acceptable standards.
Heater - 240V, 3500W
500.0 OHMS +/- 10% PS1448
225.0 OHMS +/- 10% PS1007
690.0 OHMS +/- 10% PS1448
12.3 OHMS +/- 10% PS1147
16.4 OHMS +/- 10% PS1148
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
11
208 - -
33
240 43.7 14.6
(AMPS) (AMPS)
240 25.2 14.6
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
(AMPS) (AMPS)
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
(AMPS) (AMPS)
11
11
240 43.7 14.6
33
33
220 40.1 13.4 - - -
- - - 416 14.6 14.6
- - -
208 29.2 16.8
380 13.4 13.4
- - -
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
33
11
400 13.9 13.9
- - -
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
LINE
HEATER
PHASE VOLTAGE CURRENT CURRENT
1111
33
33
- - -- - -
380 13.4 13.4
416 14.6 14.6
(AMPS) (AMPS) (AMPS) (AMPS)
(AMPS) (AMPS)
WINSTON
17
LIT.6710/REV.0/9-91
AUSTRALIA NEW ZEALAND SOUTH AFRICA
USA & CANADA MALAYSIA/SINGAPORE MALAYSIA/SINGAPORE
ENGLAND/ ENGLAND/
DESCRIPTION OHMIC VALUE PART NO
Seitenansicht 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 306 307

Kommentare zu diesen Handbüchern

Keine Kommentare